Redlands XRF machines are the most accurate, economical, and globally accepted testing machines in the RoHS segment. The EDX 2800 is widely favored by customers due to its rigid, strong design and long-term stability in performance.
This model features the most advanced Si pin detector with superior resolution, achieving precise alloy identification. Its unique wide and spot scanning capabilities, thanks to the multi-collimator facility, make the EDX 2800 the most accurate and precise RoHS testing machine available.
The larger sample chamber can accommodate any sample, and the 20 mm wide-area scanning ensures accurate results by averaging different portions of the sample. Additionally, the point collimator can analyze a precise spot valuation even after minimal surface preparation.
With its non-destructive analysis, your valuable samples remain intact throughout the testing process. When testing, users can input details like sample name and description, making our software unique in the industry.
The weight integration facility helps in exact analysis according to weight and provides future reference for transactions. Redlands advanced software features a warning alert that activates within 5 seconds if the samples contain restricted substances, necessitating further verification or investigation.
All tested results are saved in records, allowing for easy retrieval of data by sample name or date. The printout includes all necessary data, including an image of the tested sample. The conclusive and comprehensive evaluation report makes the EDX 2800 RoHS testing machine extremely helpful for users, facilitating easy compliance and record maintenance.
Redlands Ashlyn is the global leader and the most trusted XRF brand, with over three decades of experience and expertise, and a PAN India service network.
Specification | Details |
---|---|
X-ray source | X-ray Tube Ti or W cathode |
HV generator | 50kv adjustable in 200V steps Current adjustable in 1 µA steps |
Detector | Semiconductor pin diode |
Detection range | Ca(Z=20) to U(Z=92) |
Measurement range | 0.1 – 99.99% |
Measurement time | 30 – 300 seconds |
Measurement precision | ±0.1%- Inhomogeneously melted sample (Accuracy levels in comparison with fire assay result only) |
Measurement area | 1 mm to 20 mm |
Working temperature | 15 – 25 ℃ |
Relative humidity | 10 – 80 % |
System requirement | External PC with Windows 7/8/10/11 |
Collimators and Filters | 6 collimators and 5 filters automatically switched as per requirements |
Power requirement | 230 V, 50 Hz |
Power consumption | 100 W |
Dimension | 560mm X 415mm X 310mm |
Sample Chamber | 465 mm x 295 mm x 100 mm |
Weight | 48 Kg |
Rubber & Plantation-Spices & ExtractionsFood Processing, Sea Food & Cashew |